Hospital Grade Thermometers Comparison Essay

A medical thermometer is used for measuring human or animal body temperature. The tip of the thermometer is inserted into the mouth under the tongue (oral or sub-lingual temperature), under the armpit (axillary temperature), or into the rectum via the anus (rectal temperature).

History[edit]

The medical thermometer began as an instrument more appropriately called a water thermoscope, constructed by Galileo Galilei circa 1592–1593. It lacked an accurate scale with which to measure temperature and could be affected by changes in atmospheric pressure.[1][2]

Italian physician Santorio Santorio is the first known individual to have put a measurable scale on the thermoscope and wrote of it in 1625, though he possibly invented one as early as 1612. His models were bulky, impractical and took a fair amount of time to take an accurate oral reading of the patient's temperature.[1][2]

There are two particular men who switched out water for alcohol in the thermometer. The earliest is Ferdinando II de' Medici, Grand Duke of Tuscany (1610–1670), who created an enclosed thermometer that used alcohol circa 1654.[2]Daniel Gabriel Fahrenheit (1686–1736), a Polish-born Dutch physicist, engineer, and glass blower, made contributions to thermometers as well. He created an alcohol thermometer in 1709 and later innovated the mercury thermometer in 1714. Mercury, he found, responded more quickly to temperature changes than the previously used water. Fahrenheit also created the temperature scale which is named after him, having recorded the system in 1724. The scale is still only mainly used for everyday applications in the United States, its territories and associated states (all served by the U.S. National Weather Service) as well as the Bahamas, Belize, and the Cayman Islands.[1][2][3][4]

Prominent Dutch mathematician, astronomer and physicist Christiaan Huygens created a clinical thermometer in 1665, to which he added an early form of the centigrade scale by setting the scale to the freezing and boiling points of water.[1] By 1742 Swedish astronomer Anders Celsius created the Celsius temperature scale that was the reverse of the modern scale, in that 0 was the boiling point of water, while 100 was freezing. It would later be reversed by Swedish botanist Carolus Linnaeus (1707–1778) in 1744.[2][5]

Working independently of Celsius, the Lyonnais physicist Jean-Pierre Christin, permanent secretary of the Académie des sciences, belles-lettres et arts de LyonFR, developed a similar scale in which 0 represented the freezing point of water and 100 represented boiling.[6][7] On 19 May 1743 he published the design of a mercury thermometer, the "Thermometer of Lyon" built by the craftsman Pierre Casati that used this scale.[8][9][10]

The medical thermometer was used by Dutch chemist and physician Hermann Boerhaave (1668–1738), as well as his notable students Gerard van Swieten (1700–72) and Anton de Haen (1704–76). It was also utilized around the same time by Scottish physician George Martine (1700–1741). De Haen made particular strides in medicine with the thermometer. By observing the correlation in a patient's change in temperature and the physical symptoms of the illness, he concluded that a record of one's temperature could inform the doctor of a patient's health. However, his proposals were not met with enthusiasm by his peers and the medical thermometer remained a scarcely used instrument in medicine.[1]

Thermometers remained cumbersome to transport and use. By the mid 19th century, the medical thermometer was still a foot long (30.28 cm) and took as long as twenty minutes to take an accurate temperature reading. Between 1866-1867, Sir Thomas Clifford Allbutt (1836–1925) designed a medical thermometer that was much more portable, measuring only six inches long and taking only five minutes to record a patient's temperature.[1][2]

In 1868, German physician, pioneer psychiatrist, and medical professor Carl Reinhold August Wunderlich published his studies that consisted of over one million readings from twenty-five thousand patients' temperatures, taken in the underarm. With his findings, he was able to conclude a healthy human's temperature fell within the range of 36.3 to 37.5 °C (97.34 to 99.5 °F).[1]

Dr. Theodor H. Benzinger (13 April 1905 - 26 Oct 1999) invented the ear thermometer in 1964. Born in Stuttgart, Germany, he immigrated to the U.S. in 1947 and became a naturalized citizen in 1955. He worked from 1947 to 1970 in the bioenergetics division at the Naval Medical Research Center in Bethesda, Maryland.[11][12]

Classification by location[edit]

The temperature can be measured in various locations on the body which maintain a fairly stable temperature (mainly sub-lingual, axillary, rectal, vaginal, forehead, or temporal artery). The normal temperature varies slightly with the location; an oral reading of 37 °C does not correspond to rectal, temporal, etc. readings of the same value. When a temperature is quoted the location should also be specified. If a temperature is stated without qualification (e.g., typical body temperature) it is usually assumed to be sub-lingual. The differences between core temperature and measurements at different locations, known as clinical bias, is discussed in the article on normal human body temperature. Measurements are subject to both site-dependent clinical bias and variability between a series of measurements (standard deviations of the differences). For example, one study found that the clinical bias of rectal temperatures was greater than for ear temperature measured by a selection of thermometers under test, but variability was less.[13]

Oral[edit]

Oral temperature may only be taken from a patient who is capable of holding the thermometer securely under the tongue, which generally excludes small children or people who are unconscious or overcome by coughing, weakness, or vomiting. (This is less of a problem with fast-reacting digital thermometers, but is certainly an issue with mercury thermometers, which take several minutes to stabilise their reading.) If the patient has drunk a hot or cold liquid beforehand time must be allowed for the mouth temperature to return to its normal value.[14]

The typical range of a sub-lingual thermometer for use in humans is from about 35 °C to 42 °C or 90 °F to 110 °F.

Armpit[edit]

The armpit (axilla) temperature is measured by holding the thermometer tightly under the armpit. One needs to hold the thermometer for several minutes to get an accurate measurement. The axillary temperature plus 1 °C is a good guide to the rectal temperature in patients older than 1 month.[15] The accuracy from the axilla is known to be inferior to the rectal temperature.[16]

Normal Thermometer[edit]

Main article: Rectal thermometry

Normal Thermometer temperature-taking, especially if performed by a person other than the patient, should be facilitated with the use of a water-based personal lubricant. Although Normal temperature is the most accurate, this method may be considered unpleasant, or embarrassing in some countries or cultures, especially if used on patients older than young children; also, if not taken the correct way, Normal temperature-taking can be uncomfortable and in some cases painful for the patient. Normal temperature-taking is considered the method of choice for infants.[17]

Ear[edit]

The ear thermometer was invented by Dr. Theodor H. Benzinger in 1964. At the time, he was seeking a way to get a reading as close to the brain's temperature as possible, since the hypothalamus at the brain's base regulates the core body temperature. He accomplished this by using the ear canal's ear drum's blood vessels, which are shared with the hypothalamus. Before the ear thermometer's invention, easy temperature readings could only be taken from the mouth, rectum or underarm. Previously, if doctors wanted to record an accurate brain temperature, electrodes needed to be attached to the patient's hypothalamus.[12]

This tympanic thermometer has a projection (protected by a one-time hygienic sheath) that contains the infrared probe; the projection is gently placed in the ear canal and a button pressed; the temperature is read and displayed within about a second. These thermometers are used both in the home and in medical facilities.

There are factors that make readings of this thermometer to some extent unreliable, for example faulty placement in the external ear canal by the operator, and wax blocking the canal. Such error-producing factors usually cause readings to be below the true value, so that a fever can fail to be detected.[citation needed]

Temporal artery[edit]

A temporal artery thermometer, which uses the infrared principle report temperature, were not very accurate and therefore caution should be used.[18]

Forehead[edit]

The band thermometer is applied to the patient's brow. It is typically a band coated with different temperature-sensitive markings using plastic strip thermometer or similar technology; at a given temperature the markings (numerals indicating the temperature) in one region are at the right temperature to become visible. This type may give an indication of fever, but is not considered accurate.

Classification by technology[edit]

Liquid-filled[edit]

The traditional thermometer is a glass tube with a bulb at one end containing a liquid which expands in a uniform manner with temperature. The tube itself is narrow (capillary) and has calibration markings along it. The liquid is often mercury, but alcohol thermometers use a colored alcohol. Medically, a maximum thermometer is often used, which indicates the maximum temperature reached even after it is removed from the body.

To use the thermometer, the bulb is placed in the location where the temperature is to be measured and left long enough to be certain to reach thermal equilibrium—typically three minutes. Maximum-reading is achieved by means of a constriction in the neck close to the bulb. As the temperature of the bulb rises, the liquid expands up the tube through the constriction. When the temperature falls, the column of liquid breaks at the constriction and cannot return to the bulb, thus remaining stationary in the tube. After reading the value, the thermometer must be reset by repeatedly swinging it sharply to shake the liquid back through the constriction.

Mercury[edit]

Mercury-in-glass thermometers have been considered the most accurate liquid-filled types. However, mercury is a toxic heavy metal, and mercury has only been used in clinical thermometers if protected from breakage of the tube.

The tube must be very narrow to minimise the amount of mercury in it—the temperature of the tube is not controlled, so it must contain very much less mercury than the bulb to minimise the effect of the temperature of the tube—and this makes the reading rather difficult as the narrow mercury column is not very visible. Visibility is less of a problem with a coloured liquid.

In the 1990s it was decided[19] that mercury-based thermometers were too risky to handle; the vigorous swinging needed to "reset" a mercury maximum thermometer makes it easy to accidentally break it and spill the moderately poisonous mercury. Mercury thermometers have largely been replaced by electronic digital thermometers, or, more rarely, thermometers based on liquids other than mercury (such as galinstan, coloured alcohols and heat-sensitive liquid crystals).

Liquid crystal[edit]

A liquid crystal thermometer contains heat-sensitive (thermochromic) liquid crystals in a plastic strip that change color to indicate different temperatures.

Electronic[edit]

Since compact and inexpensive methods of measuring and displaying temperature became available, electronic thermometers (often called digital, because they display numeric values) have been used. Many display readings to great precision (0.1 °C or 0.2 °F, sometimes half that), but this should not be taken as a guarantee of accuracy: specified accuracy must be checked in documentation and maintained by periodical recalibration. A typical inexpensive electronic ear thermometer for home use has a displayed resolution of 0.1 °C, but a stated accuracy within ±0.2 °C (±0.35 °F) when new.[20] The first electronic clinical thermometer, invented in 1954, used a flexible probe that contained a Carboloy thermistor.[21]

Types of Digital Thermometer

Resistance temperature detectors (RTDs)

RTDs are wire windings or other thin film serpentines that exhibit changes in resistance with changes in temperature.They measure temperature using the positive temperature coefficient of electrical resistance of metals. The hotter they become, the higher the value of their electrical resistance. Platinum is the most commonly used material because it is nearly linear over a wide range of temperatures, is very accurate, and has a fast response time. RTDs can also be made of copper or nickel. o Advantages of RTDs include their stable output for long periods of time. They are also easy to calibrate and provide very accurate readings. o Disadvantages include a smaller overall temperature range, higher initial cost, and a less rugged design

Thermocouples

Thermocouples are accurate, highly sensitive to small temperature changes, and quickly respond to changes to the environment. They consist of a pair of dissimilar metal wires joined at one end. The metal pair generates a net thermoelectric voltage between their opening and according to the size of the temperature difference between the ends. •Advantages of thermocouples include their high accuracy and reliable operation over an extremely wide range of temperatures. They are also well-suited for making automated measurements both inexpensive and durable. •Disadvantages include errors caused by their use over an extended period of time, and that two temperatures are required to make measurements. Thermocouple materials are subject to corrosion, which can affect the thermoelectric voltage

Thermistor

Thermistor elements are the most sensitive temperature sensors available. A thermistor is a semiconductor device with an electrical resistance that is proportional to temperature. There are two types of products. •Negative temperature coefficient (NTC) devices are used in temperature sensing and are the most common type of thermistor. NTCs have temperatures that vary inversely with their resistance, so that when the temperature increases, the resistance decreases, and vice versa. NTCs are constructed from oxides of materials such as nickel, copper, and iron. • Positive temperature coefficient (PTC) devices are used in electric current control. They function in an opposite manner than NTC in that the resistance increases as temperature increases. PTCs are constructed from thermally sensitive silicons or polycrystalline ceramic materials. • There are several advantage and disadvantages to using an NTC thermistor thermometer. • Advantages include their small size and high degree of stability. NTCs are also long lasting and very accurate. • Disadvantages include their non-linearity, and unsuitability for use in extreme temperatures

Contact[edit]

Some electronic thermometers may work by contact (the electronic sensor is placed in the location where temperature is to be measured, and left long enough to reach equilibrium). These typically reach equilibrium faster than mercury thermometers; the thermometer may beep when equilibrium has been reached, or the time may be specified in the manufacturer's documentation.

Remote[edit]

Other electronic thermometers work by remote sensing: an infrared sensor responds to the radiation spectrum emitted from the location. Although these are not in direct contact with the area being measured, they may still contact part of the body (a thermometer which senses the temperature of the eardrum without touching it is inserted into the ear canal). To eliminate the risk of patient cross-infection, disposable probe covers and single-use clinical thermometers of all types are used in clinics and hospitals.

Accuracy[edit]

According to a 2001 research, electronic thermometers on the market significantly underestimate higher temperatures and overestimate lower temperatures. The researchers conclude that "the current generation of electronic, digital clinical thermometers, in general, may not be sufficiently accurate or reliable to replace the traditional glass/mercury thermometers"[22][23]

Basal thermometer[edit]

A basal thermometer is a thermometer used to take the basal (base) body temperature, the temperature upon waking. Basal body temperature is much less affected than daytime temperature by environmental factors such as exercise and food intake. This allows small changes in body temperature to be detected

Glass oral thermometers typically have markings every 0.1 °C or 0.2 °F. Basal temperature is stable enough to require accuracy of at least 0.05 °C or 0.1 °F, so special glass basal thermometers are distinct from glass oral thermometers. Digital thermometers which have sufficient resolution (0.05 °C or 0.1 °F is sufficient) may be suitable for monitoring basal body temperatures; the specification should be checked to ensure absolute accuracy, and thermometers (like most digital instruments) should be calibrated at specified intervals. If only the variation of basal temperature is required, absolute accuracy is not so important so long as the readings do not have large variability (e.g., if real temperature varies from 37.00 °C to 37.28 °C, a thermometer which inaccurately but consistently reads a change from 37.17 °C to 37.45 °C will indicate the magnitude of the change). Some digital thermometers are marketed as "basal thermometers" and have extra features such as a larger display, expanded memory functions, or beeping to confirm the thermometer is placed properly.

See also[edit]

[edit]

References[edit]

Allbutt, T.C., “Medical Thermometry”, British and Foreign Medico-Chirurgical Review, Vol.45, No.90, (April 1870), pp.429-441; Vo.46, No.91, (July 1870), pp.144-156.

A medical/clinical mercury thermometer showing the temperature of 37.7 °C
different test prods (top: universal test prod, bottom: rectal test prod)
Electronic clinical thermometer
Quick test based on thermo chromic colours
  1. ^ abcdefg"A Brief History of the Clinical Thermometer". QJM. Oxford University Press. 1 April 2002. Retrieved 26 July 2016. 
  2. ^ abcdef"History of the Thermometer: Timeline created by TheArctech in Science and Technology". Timetoast.com. Timetoast. Retrieved 16 July 2016. 
  3. ^Encyclopædia Britannica "Science & Technology: Daniel Gabriel Fahrenheit" [1]
  4. ^"782 - Aerodrome reports and forecasts: A user's handbook to the codes". World Meteorological Organization. Retrieved 23 September 2009. 
  5. ^Citation: Uppsala University (Sweden), Linnaeus' thermometer
  6. ^Don Rittner; Ronald A. Bailey (2005): Encyclopedia of Chemistry.Facts On File, Manhattan, New York City. pp. 43.
  7. ^Smith, Jacqueline (2009). "Appendix I: Chronology". The Facts on File Dictionary of Weather and Climate. Infobase Publishing. p. 246. ISBN 978-1-4381-0951-0.  
  8. ^Mercure de France (1743): MEMOIRE sur la dilatation du Mercure dans le Thermométre. Chaubert; Jean de Nully, Pissot, Duchesne, Paris. pp. 1609–1610.
  9. ^Journal helvétique (1743): LION. Imprimerie des Journalistes, Neuchâtel. pp. 308-310.
  10. ^Memoires pour L'Histoire des Sciences et des Beaux Arts (1743): DE LYON. Chaubert, París. pp. 2125-2128.
  11. ^"Medical Dictionary: Ear Thermometer". enacademic.com. Academic Dictionaries and Encyclopedias. 2011. Retrieved 26 July 2016. 
  12. ^ ab"Dr. Theodor H. Benzinger, 94, Inventor of the Ear Thermometer". nytimes.com. The New York Times. 30 October 1999. Retrieved 26 July 2016. 
  13. ^Rotello, LC; Crawford, L; Terndrup, TE (1996). "Comparison of infrared ear thermometer derived and equilibrated rectal temperatures in estimating pulmonary artery temperatures". Critical Care Medicine. 24 (9): 1501–6. doi:10.1097/00003246-199609000-00012. PMID 8797622. 
  14. ^Newman, Bruce H.; Martin, Christin A. (2001). "The effect of hot beverages, cold beverages, and chewing gum on oral temperature". Transfusion. 41 (10): 1241–3. doi:10.1046/j.1537-2995.2001.41101241.x. PMID 11606822. 
  15. ^http://archpedi.jamanetwork.com/article.aspx?articleid=517797
  16. ^S.T. Zengeya and I. Blumenthal (December 1996). "Modern electronic and chemical thermometers used in the axilla are inaccurate". European Journal of Pediatrics. 155 (12): 1005–1008. doi:10.1007/BF02532519. ISSN 1432-1076. PMID 8956933. Retrieved 2010-02-26. 
  17. ^Fundamentals of Nursing by Barbara Kozier et al., 7th edition, p. 495
  18. ^Kiekkas, P; Stefanopoulos, N; Bakalis, N; Kefaliakos, A; Karanikolas, M (April 2016). "Agreement of infrared temporal artery thermometry with other thermometry methods in adults: systematic review". Journal of clinical nursing. 25 (7-8): 894–905. doi:10.1111/jocn.13117. PMID 26994990. 
  19. ^Directive 2007/51/EC as of 22 January 2013
  20. ^Specification of typical inexpensive electronic ear thermometer
  21. ^"Takes Temperature in Seconds."Popular Mechanics, November 1954, p. 123.
  22. ^Latman, NS; Hans, P; Nicholson, L; Delee Zint, S; Lewis, K; Shirey, A (2001). "Evaluation of clinical thermometers for accuracy and reliability". Biomedical Instrumentation & Technology. 35 (4): 259–65. PMID 11494651. 
  23. ^"An investigation into the accuracy of different types of thermometers"Nursing Times.net, 1 October 2002.

1School of Nursing, College of Health Science, Axum University, P.O. Box 1010, Axum, Ethiopia
2School of Nursing and Midwifery, Addis Ababa, Ethiopia

Copyright © 2016 Hadgu Gerensea and Rajalakshmi Murugan. This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

Background. Children’s decisions concerning investigation and treatment may be based on the results of temperature alone. Although the accuracy of axillary temperature measurement is affected by a number of factors, device dwell time and device type are common. Objective. Compare body temperature between glass mercury thermometer (GMT) and digital thermometer (DT). Method. Comparative descriptive study was used. A total of 101 samples were taken with convenient sampling technique, but 98 were analyzed. Statistical significance () and clinical significance (°C) were used in the analyses. Correlations and Bland-Altman plots were used to observe agreements of the recording. Results. Mean difference (MD) of 10 min GMT and DT was . Statistically significant differences were noted in 10 min GMT and DT (). But the correlations were strong positive () and all MD were at the limit of agreement in Bland-Altman plot. Clinically, it is not significant (°C). Conclusion and Recommendations. Even though statistical significant differences () were noted between 10 min GMT and DT, the strong correlation, good agreements, and clinical insignificances make DT good alternative to the traditional GMT. Their variation in temperature is not likely to change any clinical decision. So, health professionals should use DT for measuring body temperature in under-5 febrile illnesses.

1. Introduction

1.1. Background and Statement of the Problem

Body temperature is a measure of the body’s ability to generate and get rid of heat. The normal physiology is to keep body temperature within a narrow safe range in spite of large variations in environmental temperatures [1]. Maintenance of body temperature occurs through the integration of multiple body systems that interact to maintain a balance between heat loss and generation. Normal body temperature is around 37°C (98.6°F) but varies during the day. The lowest body temperature occurs in early morning hours (2 am to 4 am) and the highest temperature occurs in the late afternoon. Body temperature may also increase as a result of overdressing or strenuous exercise, especially in hot weather [2].

Febrile illness is defined as a disease characterized by an increase of body temperature more than 37.5°C resulting from infectious process. Febrile illnesses (FIs) due to different etiologic agents are the most common causes of morbidity and mortality in developing tropical and subtropical countries [3].

Many of the infectious diseases assessed, classified, and treated using the Integrated Management of Childhood Illnesses (IMCI) guidelines have fever as a secondary cause. For example, many children with upper respiratory tract infection, pneumonia, or ear infection will have fever. Severe illnesses associated with danger signs are also associated with fever, such as sepsis septicemia and meningitis. The danger signs lead to appropriate referral for the illness. Fever is also associated with malaria, dysentery, and diarrhea in children. In these patients, the cause of the fever is treated and fever is not used in decision making. While these conditions all cause fever, the management of the condition itself results in the management of the fever [4].

A thermometer is a device that measures temperature or temperature gradient, using a variety of principles. For recording body temperature, several different types of thermometers are used, such as mercury thermometers, digital thermometer, liquid crystal forehead thermometer, and infrared tympanic thermometer [1]. Observe glass mercury and digital thermometers in Figure 1.

Figure 1: Digital and glass mercury thermometer.

Body temperature in children can be measured at a number of anatomical sites using a range of different types of thermometers, including mouth, rectum, and axilla [5]. Ideally, measurement should be reliable, noninvasive, nontraumatic, culturally acceptable, user friendly, and hygienic. Since rectal temperature measurements are relatively more time-consuming, invasive, uncomfortable, less hygienic, and unacceptable in many cultures, and oral temperature is unhygienic and difficult in children, axillaries measurements have been the method of choice in many countries [6–8].

Evaluation of body temperature is one of the oldest known diagnostic methods and is still an important sign of health and disease, both in everyday life and in medical care. The individual can describe feelings of illness and discomfort, but in conditions where individuals are unable to explain themselves, for example, children, the nurse has to interpret the clinical signs and rely on objective measurements [9]. Change in body temperature is one of the most important physical sign and symptom in both acute febrile illness and chronic illnesses in children. This is especially important in newborns, in which fever can be indicative of infection. It was shown that temperature out of the normal range is closely related to the survival of infants [6, 7, 10, 11]. Many decisions concerning the investigation and treatment of children may be based on the results of temperature measurement alone [12, 13].

As the basic sciences develop, temperature measurement methods and devices were improved. For hundreds of years, both in clinics and in home, GMT was the standard of human temperature measurements [14] and currently developing countries are using it commonly [15] though it is no longer recommended [11, 13, 16–19]. DTs are widely used by healthcare professionals as an alternative to GMT as they are faster and easier to read and avoid the environmental concerns of mercury [5, 19].

Although accuracy of axillary temperature measurement is affected by a number of factors, including ambient temperature, local blood flows, inappropriate placing of the probe, closure of the axillary cavity, and device dwell time, device type is common which can led to false high readings which may lead to expensive and painful diagnostic studies and medical interventions or false low readings which may lead to greater morbidity and mortality. So, temperature measurement must be accurate and consistent, as decisions about therapeutic intervention are based on it [9, 20–24].

The accuracy of devices to record and grade temperature is uncertain [1]. Limited researches have addressed whether the thermometer correctly identifies patients with hyperthermia or hypothermia. In general, these studies indicate that noninvasive temperature measurements are accurate in ruling out hyperthermia and hypothermia, but they may fail to detect hyperthermia and hypothermia, depending on the thermometer used. In particular, there is controversy in alternative approach of digital to mercury thermometers regarding accuracy and sensitivity [25]. So, this study may address the gap among health professionals.

1.2. Rationale and Significance of the Study

Temperature taking is the most frequently performed clinical observation and is predominantly a nursing task. Although the use of digital thermometer is gradually increasing, GMT is still the most common device used in the pediatric setting, especially in developing countries [15] in spite of having long dwelling time, danger of breakage, potential harm and toxic vapor effects; difficulties in reading, and possible role in spread of hospital acquired infections [11, 13, 16–19, 26].

Current nursing studies on temperature measurement are conducted to understand the efficacy of the various types of equipment available to measure temperature [27–29], but they are insufficient and contradictory [30]. In particular, there is debate between GMT and DT regarding their accuracy in measuring true body temperature and their ability to detect fever and hypothermia. Researches on those devices are scarce besides the manufacturer’s data sheets. Even the little documented studies have large discrepancy and health professionals are in debate. Due to inconsistencies in both research methods and clinical practice [31, 32], nurses are challenging in selecting the measurement method that is most appropriate for a patient and provides the most accurate and precise approximation of core temperature [33].

The false low and false high result related to accuracy of thermometer device and dwelling time may lead to misdiagnosis and treatment. If DTs are to become the standard device used in the clinical setting, they must be subjected to rigorous investigations to increase the knowledge of practitioner and thereby improve practice.

Febrile illnesses are the most common leading cause of morbidity and mortality in under-5 children which needs accurate measurement of body temperature. Ethiopia is one of the developing countries which use both GMT and DT in measuring body temperature with the uncertainty of the device and dwelling time in their capability of detecting hyperthermia and hypothermia. So, it is important to know the standard time and accurate device to measure body temperature.

This study fills the gaps among health professionals and has some input on nursing body of knowledge. It will have contribution for decision makers and significant others to take possible measure on temperature measurement device. It may decrease misdiagnosis of febrile illness in under-5 children related to inaccuracy of body temperature measurement due to devices type. This study will also be used as a base line data for further research on comparison of temperature measuring devices related topics. It is designed to investigate whether DT is suitable alternative to GMT in children.

1.3. Research Questions

Can digital thermometer be used as alternative device with old standard GMT in axillary site in under-5 children with febrile illness?

2. Objectives

Compare body temperature between 10 min glass mercury and digital thermometers among under-5 children with febrile illness at axillary site in Axum Saint Mary Hospital.

3. Methodology

3.1. Study Area

The study was carried out in Axum, city of northern Ethiopia, 1024 Km north of Addis Ababa and 241 Km far from Mekelle which is the capital city of Tigray region, located in the Central Zone of Tigray Region near the base of the Adwa mountains and surrounded by La’ilay Maychew woreda. Axum was the original capital of the kingdom of Axum and one of the oldest continuously inhabited places in Africa. Saint Marry Hospital is one of the 13 governmental hospitals found in Tigray region which serve medical care for Axum’s population and nearby. In Tigray region 16.9% of the population is under-5 years and Axum town have around 7,490 numbers of children less than five years according to city administration report in 2012 [34].

St. Marry Hospital is one of the referral hospitals in the zone in which FI is prevalent. At the time of my clinical experience, nurses working in the hospital and clinical students was debated regarding the devices even the controversy was as national. Since accurate diagnoses of FI were needed hospital were best than health center. This was why the study focused on this area. Similarly as the generalizability was to the devices, study area may not have effect.

3.2. Study Period

The Study was conducted from November/2013 to May/2014. The data was collected from 21–29/4/2014 G.C.

3.3. Study Design

Comparative descriptive study design was used to compare body temperature between GMT and digital thermometer among under-5 children with FI at axillary site in Axum St. Marry Hospital.

3.4. Source and Study Population
3.4.1. Source Population

The source population was all under-5 age children with FI visiting Axum St. Marry Hospital for healthcare service.

3.4.2. Study Population

The study population was under-5 children with FI visiting Axum St. Marry Hospital for healthcare service, particularly in under-5 OPD.

3.5. Inclusion and Exclusion Criteria
3.5.1. Inclusion Criteria

Inclusion criteria were children under 5 years of age with FI visiting Axum St. Mary Hospital particularly under-5 OPD at the time of data collection

3.5.2. Exclusion Criteria

Patients with local infection in axilla, lethargy, or unconscious were excluded. Irritable subjects were also excluded.

3.6. Sample Size Determination

A total of 96 samples were calculated using the mean difference of 10 min GMT and DT (0.27) and SD 0.54 and 0.42 (pooled SD = 0.484) at alpha of 0.01 with detection capability (power) of 90% (beta 0.1) and taking 1 as ratio of exposed to nonexposed using open Epi statistical software. 5% of 96 were added so the total of 101 study subjects were taken. But 3 were discarded in the analysis because of incompleteness and being unreadable. Manually, the study was also calculated using the following formula:where “” was the ratio of control to experimental which is 1 : 1 so , “” is the pooled SD: 0.4837, is the mean difference, 0.27, and is the sample for each group. “” was normally deviated at 90%: 1.28, and “” was for 1% which is 2.58.

3.7. Sampling Procedures

A convenient sampling technique was used as the study has no frame. Since axillary movement exposes the mercury thermometer to the environment, which was easily affected by environmental temperature, children who were irritable were purposely excluded from the study. All under-5 children with FI visiting under-5 OPD of St. Marry Hospital fulfilling the inclusion criteria were taken until the sample size reaches 101.

3.8. Clinical Study Procedures

Study participants were under 5 years of age and body temperature was not increased or decreased intentionally.

GMT and DT were on right and left axillaries, respectively, which are selected by lottery method for the first study subject. After that, GMT and DT were exchanged with consecutive study subjects for right and left axillaries. For details, see Figure 2.

Figure 2: Diagrammatic presentation of comparison of body temperature among under-5 children.

3.9. Data Collection Procedures (Instrument, Personnel, and Data Quality Control)

The study continuously collected primary data through data collection tool which was developed after review of literatures and consultation of experts in nursing (Professor Asrat, Dr. Amsal, and Professor Brhane). For content validity, the tool was reviewed. The tool included Part I: demographic preforma and Part II: recording temperature result and observation checklist. The demographic performa was filled before starting the procedures.

All data collectors (B.S. nurses) were screened for test of visual acuity in both eyes 6/6 and trained thoroughly with close supervision for 4 days in correct positioning, calibration, reading of thermometers, and documentation based on WHO guideline of taking axillary temperature. All the temperatures were measured on Celsius (°C) scale and timed with the same stop clock except for digital which have beep sound.

The validity and reliability of GMT and DT were cheeked in ICU adult who are measured by core temperature measurement prior to data collection. By marking the least valid GMT and DT, all thermometers were left for 5 min in water bath three times. Of these, the four thermometers gave the same value. Of the 5 GMT and DT, 3 GMT and 3 DT were used. 2 GMT and DT were excluded. The comparisons were done for the same devices only.

This study was performing measurements following manufacturer information for each of the thermometry instruments as described in the instruments and measurements section.

3.10. Variables
3.10.1. Dependent Variables

The dependent variables were accuracy of body temperature result.

3.10.2. Independent Variables

Temperature Variation Variables. Device type (GMT, DT)and dwelling time of GMT (5 min and 10 min) were the study variables

Covariant Variables. Route of measurement, right and lift axilla, placement of probe, environment, local blood flow, closure of axilla, taking antipyretic medication, taking bath within 30 min, time (morning, afternoon), and type of FI were the covariant variables.

3.11. Scale of Measurements

For body temperature, degree Celsius scale of measurement was used in both GMT and DT. For time in GMT, minute was scale of measurement, whereas beep sound was used in DT.

3.12. Data Analysis Procedures

First, the data were entered and coded to Epi info version 3.5.4 and exported to SPSS version 21 of Window 7 for analyses. Descriptive statistics was used to describe participants’ demographic characteristics and temperature result (hypothermia, normal, pyrexia, and hyperpyrexia) by percentage, mean, standard deviation, and range. Correlation was determined by Pearson correlation coefficient (to determine the strength of the correlation) while the extent of agreement was assessed with Bland-Altman plot. To determine statistically significant difference, a paired -tests was used. was considered statistically significant. Not only statistical but also clinical significance was also considered in the analyses. Even though the standard clinical significance varies with different literatures, most of them use a mean difference of 0.2°C and above as clinical significance [35–37]. This study also used mean difference of 0.2°C and above as clinical significance.

3.13. Data Quality Management

Examination of visual acuity was given for data collectors. Similarly, training for data collectors was given. Content validity was checked by experts. Pretest was conducted on 10 children in under-5 OPD of Axum health center. After this pretest, some modifications were incorporated. Close supervision during data collection procedures and proper recordings were also taken. Immediate checkup was carried out and any unfulfilled data was filled immediately.

3.14. Ethical Considerations

Institution Review Board (IRB) of Addis Ababa University, College of Health Science, School of Allied Health Sciences, Department of Nursing and Midwifery, reviewed the protocol to insure full protection of the rights of study subjects. Following the approval by IRB, official letter of cooperation was written to Axum St. Marry Hospital from the Department of Nursing and Midwifery of AAU. After getting permission from Axum St. Marry Hospital, data collectors informed parents verbally and at least one parent was present during the data collection. Data was treated confidentially and subject were identified by number only. Since it is axillary, it is safe and measurements were taken at OPD during assessment. It took 15 min to take all measurements for one study subject. So, it has no treatment and investigation delay. As the sampling is convenience, irritable subjects were not also forced. Risk of skin irritation was informed with informed consent. Any breakage of GMT was disposed to be appropriate as it is environmental hazard. Probe was cleaned according to service manual instructions (Welch Allyn, Inc.) prior to use for individual study subject as this prevents risk of infection.

4. Result and Discussion

4.1. Result
4.1.1. Sociodemographic Characteristics

A total one hundred and one study subjects were included in the study, but ninety-eight (97%) of them were analyzed. three were excluded because of their incompleteness and being unreadable. Sixty-six (67.3%) were collected in the morning. Fifty-three (54.1%) were female. Thirty-four (34.7%) of the children aged from 1 to 3 years. Ninety (91.8%) and 96 (98%) were not taking antipyretic and bath 30 min prior to temperature measurements, respectively. For further details, see Table 1.

Table 1: Sociodemographic characteristics of under-5 children with febrile illnesses in under-5 OPD.

Most of the under-5 children in the study were diagnosed with pneumonia which accounts for 35 (35.7%). For further details, see Figure 3.

Figure 3: Diagnosis of under-5 children with febrile illnesses in under-5 OPD.

4.1.2. Temperature Differences between 10 min GMT and DT

In this study, one reading was for 10 min glass mercury thermometer and digital thermometer for each study subject. The procedure was carried out for 98 subjects. This resulted in 98 temperature readings for each 10 min GMT and digital thermometer. The mean temperature of 10 min GMT and digital was 37.30 ± 0.78. See Table 2.

Table 2: Mean, SD, and range of temperature results of 10 min glass mercury and digital thermometers.

The maximum and minimum difference of 10 min mercury and DT was 0.4°C and 0.1°C, respectively. But 19 have no difference.

Only 13 (13.3%) of the 98 paired measurements of each 10 min GMT and DT had temperature difference greater than 0.2°C, respectively. For further details, see Table 3.

Table 3: Frequency of the difference of temperature in °C between 10 min glass mercury and digital thermometers.

44 outof 98 measurments were resulted in normal temperature by GMT and DT. For further details, see Table 4.

Table 4: Frequency of grading fever by thermometers.

The mean difference of 10 min GMT and DT was 0.12857 ± 0.10745.

4.1.3. Correlation Analyses between 10 min GMT and DT

10 min GMT has strong positive correlation with DT. The Pearson correlation () of 10 min GMT and DT was 0.99 which implies the fact that as the result of 10 min GMT increases, the result of DT also increases. Both have direct positive relation (Table 5 and Figure 4).

Table 5: Correlation between 10 minute glass mercury and digital thermometers.

Figure 4: Correlation of 10 min glass-mercury and digital thermometers.

4.1.4. Paired t-Test and Bland-Altman Analyses between 10 min GMT and DT

Statistically significant mean differences were noted in comparisons of temperatures of 10 min GMT with DT (), but there were no clinical differences (defined as a mean difference of 0.2°C). For details, see Table 6.

Table 6: Mean differences between comparison groups.

Mean differences of 10 min GMT and DT in relation to sociodemographic and other factors were done. But no clinically significant mean difference was observed (Table 7).

Table 7: Comparison groups in relation to sociodemographic and other variables.

In order to determine the concordance between GMT and DT, the Bland-Altman method of analysis was used.

Figure 5 represents Bland-Altman plot of the 10 min mercury temperature readings and the digital temperature readings. On -axis, the mean of the mercury and the digital temperature is plotted, and on -axis the difference between the temperature readings of 10 min mercury and digital thermometer is plotted. In this plot, a line of mean difference and the lines of 99% limits of agreements are presented. All of the readings were falling within the lines of limits of agreement, that is, upper limit of 0.4 and lower limit of −0.1487.

Figure 5: Bland-Altman plot of 10 min glass mercury and digital thermometers.

The horizontal line in the middle indicates the mean difference of two measurements, and two additional lines indicate above and below the mean (upper and lower limit of agreement)

Figure 5 shows 10 min GMT was higher in 75 individuals than DT. Similarly, DT was higher in 4 individuals than 10 min GMT as DT was subtracted from 10 min GMT.

10 min GMT and DT was agreed on in 88 of 98 measurements (For further details, see Table 8).

Table 8: Agreement of 10 min glass mercury with digital thermometers in specific range of temperature.

4.2. Discussion

Due concerns about the breakages and environmental hazards of digital thermometers have evolved with the hope of replacing the glass mercury thermometer. The importance of the speed of application and the ease of use of DT is important in busy clinical area, but accuracy must be a primary concern.

The present study was conducted to find the concordance of the digital thermometer with the glass mercury thermometer with the hypothesis that there are statistical significant mean differences in temperature result between 10 min GMT and DT.

The participant characteristics of this study were under-5 children who had febrile illness unlike the study conducted in Turkey (healthy infants and healthy young students aged from 18 to 24), India (health neonates), and Malaysia (all age group with illness) [19, 27, 38]. Similarly, this study measured temperature at auxiliary which was consistent with other studies in Turkey, India, and Korea, [19, 27, 39], but not with Malaysia which was on oral site [38]. Most of the previous studies used only statistical test [36, 39–48] unlike this study, which used both statistical and clinical implications in the overall decision of the research hypothesis.

The mean difference of 10 min GMT and DT in this study showed a statistical significance (). This finding was supported from the study of Biomedical Instrumentation and Technology which indicates that the improvements in safety, speed, and simplicity of use of the DT have been offset by statistically significant difference. Latman states that “the current generation of electronic, digital clinical thermometers, in general, may not be sufficient to replace the traditional glass/mercury thermometers” [49].

But from the point of clinical importance, the mean difference (0.13) of 10 min and DT of this study was not of clinical significance. 99% of the mean differences were between 0.10 and 0.16, which are not clinically significant. The correlation also showed strong positive correlation () and all the mean differences were also falling in the limit of the agreement. These results were similar to the studies conducted in Iran and USA in which digital thermometers gave the best concordance with mercury thermometers [18, 50, 51].

The variation of temperature between 10 min GMT and DT was not homogeneous (consistent). Furthermore, the mean difference observed between 10 min GMT and DT was not clinically significant, so no compensation for the differences was needed.

But one study found that GMT and DT were clinically and statistically significant with mean difference of 0.278 and [38]. This difference might be because of the route difference, since the study was conducted in oral route in which GMT were highly influenced by ingestion of food prior to 30 min. Similarly, the measurements were not taken simultaneously unlike this study.

4.2.1. Conclusion

Even though a statistical significance () difference was observed between 10 min GMT and DT, their mean differences were not clinically significant (<0.2°C) or do not differ enough to cause problems in clinical interpretation. Their correlations were also strong positive correlation () and all the mean differences among them were falling in the limit of agreement in Bland-Altman plot. Their variation in temperature is not likely to change any clinical decision. No compensation for the difference is needed since lack of consistent mean differences (homogeneous variations) between GMT and DT was shown. Similarly, their differences were clinically not significant.

Statistically, the alternative hypothesis was not rejected. But this statistical significance cannot prejudice the alternative approach of DT because the clinical insignificances observed were most important (the primary concern).

Generally, the strong correlations, good agreements, and clinical insignificances observed make DT good alternative to the traditional GMT. Similarly, some important disadvantages of GMT, such as danger of breakage, potential harm and toxic vapor effects, difficulties in reading the values on the device, possible role in spread of hospital acquired infection, and long dwelling time, and advantage of DT, such as rapid result delivery, improved patient comfort, being an easy and noninvasive procedure, also support this alternative approach. Therefore,(i)health professionals should use DT for measuring body temperature in under-5 febrile illnesses as it has no clinical significance difference with GMT and has some advantages over GMT (being easy to read, having fast result, and being environmentally friendly) [5, 19];(ii)researchers should further study the instruments in neonates as clinical significance is different from the present study and the age groups were few. Similarly, the sensitivity may differ from other since their skin integrity is different. Likewise, their concordance in detecting hypothermia should be investigated since the sensitivity may differ;(iii)Moreover, researchers should repeat the study by using core temperature as the gold standard for comparison since comparison of DT with GMT may have additive effect of deviation from core temperature;(iv)FMHACA should focus on DT rather than GMT as it has no clinical significance difference with GMT and have some advantages over GMT (being easy to read, having fast result, and being environmentally friendly) [5, 19].

Conflict of Interests

The authors declare that there is no conflict of interests regarding the publication of this paper.

Acknowledgments

The authors are very grateful and would like to extend their heartfelt thanks and appreciation to the study participants and data collectors for their full participation and for supporting data collection. Finally, they would like to acknowledge Addis Ababa University, College of Health Sciences, School of Allied Health Sciences, Department of Nursing and Midwifery, for giving them this great opportunity.